Inspection
Inspection Details
Equipment ID
4402
4402
Inspection Date
8/10/2018
8/10/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
John Ryan
John Ryan
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
490
490
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
45bf4418-9b1e-4c1b-8e12-83cb98965d00
45bf4418-9b1e-4c1b-8e12-83cb98965d00
Location
Piper Medical Bldg
112 PIPER HILL DR, SAINT PETERS, MO
112 PIPER HILL DR, SAINT PETERS, MO
Owner
Piper, Terrance
112 PIPER HILL DR, SAINT PETERS, MO 63376-1690
112 PIPER HILL DR, SAINT PETERS, MO 63376-1690
Billing
Attn: St. Peters Office Associates
4800 MEXICO RD STE 105, SAINT PETERS, MO 63376-1666
4800 MEXICO RD STE 105, SAINT PETERS, MO 63376-1666
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | An ABC fire extinguisher with a current test tag shall be provided convenient to the machine room access door. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | No | No | The machine room shall not be used for storage of non-elevator related materials. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Instructions for locating maintenance records shall be posted as required by A17.1 2016 - 8.6.1.4.2 | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A checkout procedure for the 2 way communication system shall be provided by A17.1 2016 - 8.6.1.2.2(c)(3) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A checkout procedure for the over-speed valve shall be provided by A17.1 2016 - 8.6.1.2.2(c)(5) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | An evacuation procedure shall be made available as required by A17.1 2016 - 8.6.1.2.2(d)(1) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A call-back log shall be provided as required by A17.1 2016 - 8.6.1.4.2 | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 12/3/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | No | No | Machine room shall be for elevator equipment only. | 4/17/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency lighting shall work. | 12/12/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Non-elevator related items shall not be stored in the machine room. (file cabinet, office chair, ect) | 12/12/2025 |