Inspection
Inspection Details
Equipment ID
2527
2527
Inspection Date
9/14/2022
9/14/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Willie Smith
Willie Smith
Mechanic Name
Thomas Nash
Thomas Nash
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
24
24
External ID
71834486-a064-4072-8a84-2bb6d3a99b80
71834486-a064-4072-8a84-2bb6d3a99b80
Location
Hearnes Multipurpose Bldg
E Stadium Blvd at Tiger Ave, Columbia, MO
Phone: (573) 882-6463
E Stadium Blvd at Tiger Ave, Columbia, MO
Phone: (573) 882-6463
Owner
Attn: Debra Anderson - Facility Operations
UMC-General Services
180 General Services Bldg, Columbia, MO 65201
Phone: (573) 884-5300
Email: mumuopselevatorin1@missouri.edu
UMC-General Services
180 General Services Bldg, Columbia, MO 65201
Phone: (573) 884-5300
Email: mumuopselevatorin1@missouri.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | Yes | No | No emergency telephone | 8/21/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | No audible indication of Phase 1 Fire Service Recall | 8/21/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 4/1/2021 |
| A17.1-2016 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(b) | No | No | Profide safe access to overhead govenor installation, current vertical ladder in excess of 20ft with access door extending over ladder while opening. a plate form must be provided to stand on while opening door. Access must be OSHA compliant, door must be marked "danger elevator hoistway" | 4/1/2021 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(f) | No | No | A remote stop switch and a light should be installed at overhead govenor which is a remote work space to provide a safe working environment | 4/1/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Provide a light in top of hoistway at goverence with 10 switch on wall outside access door | 9/24/2021 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(f) | No | No | A remote stop switch should be installed in overhead when governor is located | 1/28/2026 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(f) | No | No | Provide lighting in governor overhead which is a remote work space tp provide a safe working enviroment | 1/28/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Light in hoistway was not working on day of inspection | 1/28/2026 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | A remote stop switch should be installed in overhead where Governor is located | 1/28/2026 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | Provide lighting in governor overhead which is a remote work space, to provide a safe working environment | 1/28/2026 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | Light in hoistway was not working on day of inspection | 1/28/2026 |