Inspection
Inspection Details
Equipment ID
2569
2569
Inspection Date
9/19/2022
9/19/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Willie Smith
Willie Smith
Mechanic Name
Thomas Nash
Thomas Nash
Relief Valve Pressure
Slide
NA/NA
NA/NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
25
25
External ID
3a756f08-ec94-48b2-bc78-c6e579bf0a41
3a756f08-ec94-48b2-bc78-c6e579bf0a41
Location
Energy Management Power Plant
412 S 5th St, Columbia, MO
Phone: (573) 882-6463
412 S 5th St, Columbia, MO
Phone: (573) 882-6463
Owner
Attn: Debra Anderson - Facility Operations
UMC-General Services
180 General Services Bldg, Columbia, MO 65201
Phone: (573) 884-5300
Email: mumuopselevatorin1@missouri.edu
UMC-General Services
180 General Services Bldg, Columbia, MO 65201
Phone: (573) 884-5300
Email: mumuopselevatorin1@missouri.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Five year full load test needed. Last full load test performed 11/2010 | 8/5/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 11/25/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm shall work with power loss. (REINSPECTION within 30 days) | 10/30/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | No | No | sight guard needs to be re-secured at 3rd landing | 11/25/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag | 11/25/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 8/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | No | No | Post code data p[late conforming to sec 8.9 on controller | 8/3/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Additional lighting is needed in machine room | 8/26/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Light in pit is not working | 8/26/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working, needs repaired. Re-inspection required | 8/26/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 8/26/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Light is not working in pit | 8/26/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 9/9/2025 |