Inspection
Inspection Details
Equipment ID
18777
18777
Inspection Date
9/21/2022
9/21/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Jason Turner
Jason Turner
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
108e5d22-a946-481d-9339-5fb0175f4fcf
108e5d22-a946-481d-9339-5fb0175f4fcf
Location
First Baptist Church of Trenton
2600 Oklahoma Ave, Trenton, MO
Phone: (660) 359-3898
2600 Oklahoma Ave, Trenton, MO
Phone: (660) 359-3898
Owner
Attn: First Baptist Church of Trenton
First Baptist Church of Trenton
2421 Oklahoma Ave, Trenton, MO 64683
Phone: (000) 000-0000
Email: fbctrentonmo@gmail.com
First Baptist Church of Trenton
2421 Oklahoma Ave, Trenton, MO 64683
Phone: (000) 000-0000
Email: fbctrentonmo@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | Top of car emegency exit needs to be locked on the top side of the elevator. | 9/24/2024 | ||
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Post firefighters phase 2 operation instructions inside elevator. | 9/24/2024 | ||
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | Monthly test and log of firefighters operation. | 9/24/2024 | ||
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)5 | Install toe guard (apron) to car platform. | 9/24/2024 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)14 | Install beveled guard at all landing sills. Guards to extend to depth of leveling zone plus 3 inches. | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Post emergency evacuation of passengers procedure form inside machine room. | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Provide maintenance records on site, or viewable on site, of maintenance control plan. | 9/24/2024 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | Emergency exit cover needs to be attached to cartop with chain or hinge, and needs to be lockable from the car top. | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | In case of fire don't use elevator signage needed | 9/24/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door needs to be self-locking | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | MCP needed | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Provide MCP in machine room to log maintenance, repairs, and inspections. | 9/24/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non-elevator related items from machine room. (boxes) | 9/24/2024 | ||
| A17.1-2016 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 8.6.5.6 | Flexible hose from tank to shut off valve has no data tag, age unknown. Replace hose and provide new data tag. | 9/24/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | MCP has not been initiated. | 9/24/2024 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Current State Operating Certificate unavailable. | 9/24/2024 | ||
| A17.1-2016 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 8.6.5.6 | x | Flex hose in the Hydrualic Oil line located in the Elevator Machine room has never been tagged as to the installation occurred. Flex House must be replaced every six years. Or the area the hose incompasses hard piped | 9/9/2024 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Current State Operating Certificate not available. The violations noted on 9/2023 annual inspection have been corrected. | 9/24/2024 |