Inspection
Inspection Details
Equipment ID
9795
9795
Inspection Date
9/20/2022
9/20/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Aaron Bagley
Aaron Bagley
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
5b2fd198-c535-4a97-b472-b3d1c017fbb8
5b2fd198-c535-4a97-b472-b3d1c017fbb8
Location
The Dome
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
Owner
Attn: America's Center
America's Center
701 Convention Plz, St. Louis, MO 63101
Phone: (314) 342-5118
Email: mgruhala@explorestlouis.com
America's Center
701 Convention Plz, St. Louis, MO 63101
Phone: (314) 342-5118
Email: mgruhala@explorestlouis.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide written maintenance control program to include wiring diagrams to be kept on site. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform unit clean down and repair seals causing oil leak on steps. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Top right comb plate has 2 missing teeth, needs replaced | 6/4/2026 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current certificate | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.13 Escalator Handrail Safety Systems | Yes | No | Provide Category 1 testing.of handrail | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Provide Category 1 testing.of step/ skirt index | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(A) | Yes | No | Provide Category 1 testing.of brake torque. | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | Yes | No | Provide Category 1 testing, lower center comb. | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.14 Escalator Entrance and Egress Ends | Yes | Yes | Screws broken off upper center comb plate during testing, unit removed from service. | 9/20/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform complete clean down to remove oil leaking from drive machine. | 6/4/2026 |
| MO Minimum : Elevators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | T(1) 704 Driving Machines and Sheaves | No | No | Need to replace leaking seal on drive machine. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(F) | No | No | Repair balustrade joint on right side to match up with adjacent panel | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Unable to test brake torque because testing point is stripped. Repair or replace and re-inspect within 60 days | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current certificate | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform complete clean down to remove oil leaking from drive machine. | |
| MO Minimum : Elevators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | T(1) 704 Driving Machines and Sheaves | No | No | Need to replace leaking seal on drive machine. |