Inspection
Inspection Details
Equipment ID
23433
23433
Inspection Date
9/30/2022
9/30/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Melvin Barks Jr.
Melvin Barks Jr.
Mechanic Name
Andrew Smith
Andrew Smith
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
4d5d28c1-9211-47a8-9e25-f76af586c4d7
4d5d28c1-9211-47a8-9e25-f76af586c4d7
Location
Progressive Ozark Bank
904 W Scenic Rivers Blvd, Salem, MO
Phone: (573) 729-4146
904 W Scenic Rivers Blvd, Salem, MO
Phone: (573) 729-4146
Owner
Attn: Susan
Progressive Ozark Bank
904 W Scenic Rivers Blvd, Salem, MO 65560
Phone: (573) 453-2423
Email: smpryor@progressiveozarkbank.com
Progressive Ozark Bank
904 W Scenic Rivers Blvd, Salem, MO 65560
Phone: (573) 453-2423
Email: smpryor@progressiveozarkbank.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Only items relating to the operation of the elevator shall be stored in the machine room. All non-elevator related materials shall be removed from the machine room. | 5/13/2019 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Emergency lighting shall work. | 5/13/2019 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency alarm shall work. | 3/20/2019 | |
A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | A ABC type fire extinguisher shall be provided in the machine room. | 5/13/2019 | ||
A17.1-1996 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 1001.2(e)10 | x | A Category 5 full load test shall be witnessed. | 3/20/2019 | |
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1001.2(d)(12) - | "Do not use in case of fire" signage is required. | 5/13/2019 | ||
A17.1-1996 : Elevators | 4.2 - Hoistway doors | 1001.2(d)(2) | The distance between the inside face of the hoistway door and the edge of the landing sill shall be less than 3". | 5/13/2019 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A variance shall be requested to allow a residential elevator to be installed in a commercial application. | 5/13/2019 | ||
A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | All hoistway wiring shall be enclosed in conduit. | 5/13/2019 | ||
A17.1-1996 : Elevators | 3.14 - Hoistway clearances | 1001.2(c)(20) | x | Complete fascia is required to maintain proper car clearances. | 7/9/2019 | |
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Emergency light shall work. | 5/13/2019 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | A pit light switch is required. | 5/13/2019 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | Emergency light failed to operate during test. | 3/1/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | x | Phone, emergency bell and emergency light failed to operate. Elevator was red tagged power shut off at disconnect. Email sent to office. | 12/19/2022 |