Inspection
Inspection Details
Equipment ID
19176
19176
Inspection Date
9/19/2022
9/19/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
17
17
External ID
df7bcdb1-aa02-43dd-b1c7-0d38af6ad8f0
df7bcdb1-aa02-43dd-b1c7-0d38af6ad8f0
Location
5615 Pershing Building
5615 Pershing Ave, Ste 26, St. Louis, MO
Phone: (000) 000-0000
5615 Pershing Ave, Ste 26, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: East Gate Investment Inc
East Gate Investment Inc
7 Princeton Ave, University City, MO 63130
Phone: (314) 808-1019
Email: schoomer@swbell.net
East Gate Investment Inc
7 Princeton Ave, University City, MO 63130
Phone: (314) 808-1019
Email: schoomer@swbell.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self-closing. | 8/29/2018 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non-elevator related equipment from the machine room. | 8/29/2018 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Provide an ABC type fire extinguisher in the machine room. | 8/29/2018 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean and dry. Remove fluids from the pit. | 8/29/2018 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Determine the source of fluids in the pit and repair. | 8/29/2018 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Cab lights shall be guarded to prevent breakage. | 8/29/2018 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | The existing telephone shall work and call to a number providing 24/7 support. | 4/9/2019 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Remove the oil from the pit. | 6/24/2019 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Replace the leaking cylinder packing. | 6/24/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Items and materials not related to the function or maintenance of the elevator shall not be stored in the elevator machine room. | 11/18/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | There is no test tag on the fire extinguisher in the machine room. The fire extinguisher shall be properly tagged to indicate the expiration date and type of extinguisher. | 11/18/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 7/21/2021 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 7/21/2021 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Remove oil from the pit. The pit shall be kept clean and dry. | 7/21/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Oil is leaking in the pit. Determine the source of the oil leak and take corrective action. | 7/21/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency lighting shall be tested and work. No light disconnect in the machine room, nothing labeled as to circuit breaker location. | 3/4/2025 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self-closing and self-locking. Door has been removed. Replace door with appropriate fire rated door. | 3/23/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | Clean the car top. | 3/23/2026 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Replace damaged/missing door operator belts. | 3/23/2026 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Cab lighting - all lamps shall work. | 3/23/2026 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | Oil is leaking into the pit due to cylinder packing. Jack shall be repacked and/or proper oil collection shall be provided. Clean pit of oil/debris. | 8/22/2025 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | Missing J-box cover on ceiling. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Current fire extinguisher required in the machine room. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Current State operating certificate is required in the machine room. |