Inspection
Inspection Details
Equipment ID
24204
24204
Inspection Date
9/30/2022
9/30/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
be0c1591-ad9b-446d-9a24-ccfca1a9025e
be0c1591-ad9b-446d-9a24-ccfca1a9025e
Location
The Bordeaux
1332 Dolman St, St. Louis, MO
Phone: (314) 304-3747
Email: sid@asprient.com
1332 Dolman St, St. Louis, MO
Phone: (314) 304-3747
Email: sid@asprient.com
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(h) | Closet next to elevators is a machine space. Remove all non elevator related equipment | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(b) | Machine space doors to be self closing | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(b) | Machine room door to be self locking | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Provide MCP | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Expired | 12/7/2022 | ||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Existing phone not working. Repair as needed | 1/20/2022 | |
A17.1-2016 : Elevators | 2.11 - Disconnecting Means and Control | 8.11.2.1.2(p) | Provide feeder location on main line disconnect. | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.11 - Disconnecting Means and Control | 8.11.2.1.2(p) | Provide feeder location on 110v. disconnect. | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | Closet next to elevator is an elevator room, remove all non elevator related equipment from this space. | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | Elevator room doors are to be self closing and self locking | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 8.11.2.1.2(k) | Provide feeder location on main line disconnect | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide complete MCP | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Provide current tested fire extinguisher in elevator machine room | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work, Re-inspection required | 9/30/2022 | |
A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | Closet next to elevator is in machine space, remove non elevator equipment | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | Machine room doors need to be self closing and self locking | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Provide MCP | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Expired fire extinguisher | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4.1 | Provide feeder location on main line disconnect | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4.1 | Provide feeder location on 110 v disconnect | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Rooms and Machinery Spaces | remove all non elevator equipment from contol space | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | provide feeder location on main line disconnect | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | provide feeder location on car light disconnect | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | elevator control room door to be self locking. | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | elevator control room to be self closing. | 12/7/2022 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | provide an on-site maintenance control program. | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | provide a current tested fire extinguisher in elevator control room. | 12/7/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Fire extinguisher expired. In the main disconnect room on top floor | 10/30/2023 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display updated Missouri operating certificate in machine room. Top floor electrical room | 10/30/2023 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | x | Fire extinguisher is expired, have serviced or replaced. Re-inspection required | 10/7/2024 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Perform the following tests to complete the Cat 5 full load test. Pull out and pull through force of govenor. Tripping speed of governor switch and governor jaws. Unintended movement. car safeties at rated speed with rated load. Re-inspection required | 11/14/2024 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Fire extinguisher is expired in the main disconnect room on top floor. Have serviced or replaced | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the elevator machine room |