Inspection
Inspection Details
Equipment ID
24575
24575
Inspection Date
10/4/2022
10/4/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
28 / 26
28 / 26
External ID
cf81ed63-31dc-49fa-8f8c-e8536f3e1484
cf81ed63-31dc-49fa-8f8c-e8536f3e1484
Location
Hibernia Apartments
6300 Clayton Ave, St. Louis, MO
Phone: (314) 625-3090
Email: slcarson@rbm-partners.com
6300 Clayton Ave, St. Louis, MO
Phone: (314) 625-3090
Email: slcarson@rbm-partners.com
Owner
Attn: Shawndale Carson
Hibernia Apartments
6300 Clayton Ave, St. Louis, MO 63139
Phone: (314) 660-3032
Email: SLCarson@rbm-partners.com
Hibernia Apartments
6300 Clayton Ave, St. Louis, MO 63139
Phone: (314) 660-3032
Email: SLCarson@rbm-partners.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone in car is not working. Re-inspection required | 12/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Light in pit is not working, needs repair | 8/23/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | Yes | No | Sump pump in pit is not working, needs repair. Re-inspection required | 12/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Pit light is not working, needs repair | 8/23/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | Yes | No | Sump pump in pit is not working, needs repair. Re-inspection required | 10/20/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | Yes | Final limit switch does not work in the down direction, needs repaired. Red-tagged, Re-inspection required | 11/29/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.13 - Governor,overspeed switch and seal | 2.26.2 | Yes | No | Plunger on governor switch is broken. Switch functions, but cannot be reset without disassembling of switch, replace switch. Re-inspection required | 11/29/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Compensation rope displacement switch on bottom of elevator cab appears to have water damage and could not be reset, replace switch. Re-inspection required | 11/29/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.13 - Governor,overspeed switch and seal | 2.18 | Yes | No | Government remote trip / reset function does not work, needs repaired. Re-inspection required | 11/29/2023 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.12 | Yes | No | Plunger on governor switch is broken. Switch functions, but cannot be reset with without disassembling of switch, need to replace switch. Re-inspection required | 10/1/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Compensation rope displacement switch on bottom of elevator cab appears to have water damage and could not be reset, replace switch. Re-inspection required | 10/1/2024 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.12 | Yes | No | Governor remote trip / reset function does not work, needs repaired. Re-inspection required | 10/1/2024 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.12 | Yes | No | Governor remote trip / reset function does not work, needs repaired. Re-inspection required | 11/4/2025 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Governor rope is below minimum diameter and shall be replaced. Re-inspection required | 11/4/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 2.26.2.22 | Yes | No | Gas spring return buffers shall be equipped with a switch to disconnect power to the driving machine in the event that a buffer is not within an 1/2 inch of its fully extended position. Re-inspection required | 11/4/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be made operational. Re-inspection required | 12/30/2025 |
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)6 | No | No | Car guide shoes shall be adjusted so that the car is not floating all over the hoistway | 12/30/2025 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.6.4.12 | Yes | No | Governor remote trip / reset function does not work, needs repaired. Re-inspection required | 12/30/2025 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Governor rope is below minimum diameter and shall be replaced. Red-tagged, Re-inspection required | 12/30/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 2.26.2.22 | Yes | No | Gas spring return buffers shall be equipped with a switch to disconnect power to the driving machine in the event that a buffer is not within an 1/2 inch of its fully extended position. Re-inspection required | 12/30/2025 |