Inspection
Inspection Details
Equipment ID
1816
1816
Inspection Date
10/31/2022
10/31/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
F. Scott Gibson
F. Scott Gibson
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
390
390
Slide
Governor Rope Pull
Door Closing Force
n/a
n/a
External ID
641f8afd-e037-4645-912b-34faae227761
641f8afd-e037-4645-912b-34faae227761
Location
Smithfield Farmland
22123 Hwy 5, Milan, MO
Phone: (660) 265-4061
22123 Hwy 5, Milan, MO
Phone: (660) 265-4061
Owner
Attn: Smithfield
Smithfield
11500 N Ambassador Dr, Kansas City, MO 64153
Phone: (660) 265-4061
Smithfield
11500 N Ambassador Dr, Kansas City, MO 64153
Phone: (660) 265-4061
Billing
Attn: Dwight Barton
Smithfield
22123 Hwy 5, Milan, MO 63556
Phone: (660) 265-4061 Ext: 5333
Email: DLBarton@smithfield.com
Smithfield
22123 Hwy 5, Milan, MO 63556
Phone: (660) 265-4061 Ext: 5333
Email: DLBarton@smithfield.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Top of car inspection station does not function. | 10/9/2018 |
| conversion | conversion | n/a | No | No | Repair pit light. Pit light not working and electrical wires are exposed. | 10/9/2018 |
| conversion | conversion | n/a | No | No | elevator phone does not function. | 10/9/2018 |
| conversion | conversion | n/a | No | No | Enclose wires from hoistway duct to first floor hall button fixture in metal conduit. | 10/9/2018 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Multicable wiring from hoistway duct to first floor hall button fixture needs to be in flexible metal conduit, not plastic tubing. | 10/9/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Need to install light switch that operates pit light. Switch should be accessible from the pit access door. | 10/9/2018 |
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)5 | No | No | Need to install car platform toe guard on elevator. | 11/23/2019 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Test and log firefighter operation monthly | 1/6/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Post firefighter instructions inside the elevator | 1/6/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | No | No | CAR DOES NOT HAVE A CAPACITY / LOADING CLASS / AND ''NO PASSENGERS'' SIGNAGE | 5/5/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)6 | Yes | No | THE UPPER DIRECTIONAL SWITCH ARM HAS BEEN REMOVED MAKING THE SWITCH INOPERABLE | 4/9/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)6 | Yes | No | PHASE 1 FIRE SERVICE SWITCH DOES NOT WORK | 4/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone did not work, repair emergency phone | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water in pit, maintain dry pit | |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | First floor flex to hall button in the hoistway is broken and hanging on the wiring, repair flex | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean the car top |