Inspection
Inspection Details
Equipment ID
20880
20880
Inspection Date
8/24/2018
8/24/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Douglas Gildehaus
Douglas Gildehaus
Relief Valve Pressure
570
570
Slide
Governor Rope Pull
Door Closing Force
29F/24R
29F/24R
External ID
c27f04f5-27c6-424e-9291-06dc36a6ae43
c27f04f5-27c6-424e-9291-06dc36a6ae43
Location
Aberdeen Heights Building F
505 COUCH AVE, KIRKWOOD, MO
505 COUCH AVE, KIRKWOOD, MO
Owner
Ashfield Active Living
PO BOX 20440, WICHITA, KS 67208-1440
PO BOX 20440, WICHITA, KS 67208-1440
Billing
Attn: Ashfield Active Living
PO BOX 20440, WICHITA, KS 67208-1440
PO BOX 20440, WICHITA, KS 67208-1440
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.8 Access to Underside of Car | No | No | 2.2.8 - Access to underside of car. Where the distance from the pit floor to the underside of the plank channels or slings exceeds 2100mm (83in.), with the car at the lowest landing, a means shall be permanently installed or permanently stored in the pit to provide access to the equipment on the underside of the car. | 9/23/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 7/29/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.8 Access to Underside of Car | No | No | A permanent of temporary means shall be installed to allow access to the jack head and all piping structures in the pit. (Pit is very deep and jack head and piping cannot be reached from pit floor) | 7/29/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | A category 5 full load test shall be performed on the overspeed valve in 2022. | 7/12/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/29/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 3.26.10 (Auxiliary Power)(Re-Inspection) | Yes | No | The auxiliary power lowering operation shall be functional. An uninterruptible power supply for the emergency lowering operation was sitting on the floor of the machine room. When an elevator is equipped with this device, it has to be operational and can't be removed without the permission of the MO AHJ. See MO Memorandum 016 for more information regarding this violation. | 1/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | Yes | No | Where an additional power source is connected to the load side of the disconnecting means, the disconnecting means required in Section 620-51 shall be provided with an auxiliary contact that is positively opened mechanically and the opening shall not be solely dependent on springs. This contact shall cause the additional power source to be disconnected from its load when the disconnecting means is in the open position. | 2/24/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/29/2026 |