Inspection
Inspection Details
Equipment ID
18024
18024
Inspection Date
11/2/2022
11/2/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
420
420
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
dd252aa5-1879-4d2d-9db1-2e659ddaedd1
dd252aa5-1879-4d2d-9db1-2e659ddaedd1
Location
Harris Stowe State University-Dorm
3026 Laclede Ave, St. Louis, MO
Phone: (314) 340-3361
Alt Phone: (314) 280-9962
3026 Laclede Ave, St. Louis, MO
Phone: (314) 340-3361
Alt Phone: (314) 280-9962
Owner
Attn: Timothy McDonell
Harris-Stowe State University
3026 Laclede Ave, St. Louis, MO 63103
Phone: (314) 340-3306
Email: mcdonelt@hssu.edu
Harris-Stowe State University
3026 Laclede Ave, St. Louis, MO 63103
Phone: (314) 340-3306
Email: mcdonelt@hssu.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency telephone shall work. | 5/24/2019 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept clean and dry. | 12/2/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The oil recovery bucket is full. | 12/2/2025 |
| A17.1-1996 : Elevators | 2.36 - Hydraulic Cylinders | 1004.2(b)(19) | No | Yes | Car settled during standing test. Visible leakage at packing gland. Make necessary repairs to correct. | 11/17/2020 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 1001.2(b)(3) Inspection code | No | No | The machine room lighting shall be operational. | 12/2/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept clean. Clean the pit. | 12/2/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit light shall be operational. | 12/2/2025 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | No | No | There is an open hole in the car operating panel that shall be covered. | 12/2/2025 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | No | No | All non elevator related items and materials shall be removed from the machine room. | 12/2/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Packing was blown during the pressure test and elevator left out of service. The following testing items still need to be tested to finish annual inspection: Relief pressure test, 15 minute standing test, fire service, door pressure, ERU test, emergency phone, light, and alarm. | 11/2/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | The elevator dropped significantly during the 15 minute standing test. Take corrective action as needed. The relief pressure test and 15 minute standing test will need to be witnessed again. Elevator Red Tagged | 11/23/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) | Yes | No | The overspeed valve in not tagged or sealed. A category 5 test shall be performed and witnessed on the overspeed valve. | 11/23/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/2/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The following items still need to be tested: (1) Door pressure, (2) Testing of emergency alarm, phone and light with 110v source removed, (3) Fire service, (4) Low pressure switch. | 11/23/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. The phone did not work at all with or without the 110v power. | 12/27/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) | Yes | No | The overspeed valve in not tagged or sealed. A category 5 test shall be performed and witnessed on the overspeed valve. | 12/27/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. The phone shall be operational on main and auxiliary power. | 5/26/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational on main and auxiliary power, and give proper location of car. (2nd Notice) | 9/11/2024 |
| A17.1-1996 : Elevators | 1.2 - Stop switches | 210.2(e) | Yes | No | Repair or replace the faulty in-car stop switch. | 9/11/2024 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/2/2025 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 101.5a Lighting | No | No | The machine room lighting shall be repaired. 1 or more bulbs are not working. | 12/2/2025 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 101.1a | No | No | Repair multiple large holes in the machine room ceiling. | 5/4/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Replace unreadable in-car capacity plate. | 5/4/2026 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | The pit shall be kept clean. Remove excess debris. | 5/4/2026 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept clean. Clean the pit. | 5/4/2026 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | No | No | Machine room shall be kept clean/remove all non-elevator materials. | 5/4/2026 |
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 210.1a | No | No | Directional on door jam is missing. | 5/4/2026 |
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 1001.2(a)(3) | No | No | Hole in hoistway control panel needs to be covered. | 5/4/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emercency phone shall be operational. Can't hear other person on the line. | 5/4/2026 |
| A17.1-1996 : Elevators | 3.10 - Hoistway construction | 100 | No | No | Cove holes in the hoistway. | 5/4/2026 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Fire extinguisher is expired. | 5/4/2026 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No MO State operating certificate in the machine room. | 5/4/2026 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No State certificate in the machine room | 7/31/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | Emergency phoen not working | 7/31/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | No emergency alarm bell. | 7/31/2026 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Fire service plate is missing and shall be replaced. | 7/31/2026 |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 210.13 | No | No | replace directioanl lantern or cover hole. | 7/31/2026 |
| A17.1-1996 : Elevators | 1.16 - Rated load, platform area, and data plate | 1001.2(a)(16) | No | No | Otis capacity plate is damaged and shall be replaced. | 7/31/2026 |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | Machine room wall shall be repaired. | 7/31/2026 |
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 210.1a | No | No | Cover hole in COP. | 7/31/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | emergency phone not working. | |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No State certificate in the machine room | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Fire service plate is missing and shall be replaced. | |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 210.13 | No | No | replace directioanl lantern or cover hole. | |
| A17.1-1996 : Elevators | 1.16 - Rated load, platform area, and data plate | 1001.2(a)(16) | No | No | Otis capacity plate is damaged and shall be replaced. | |
| A17.1-1996 : Elevators | 2.4 - Machine space | 100.3d | No | No | Machine room wall shall be repaired. | |
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 210.1a | No | No | Cover hole in COP. |