Inspection
Inspection Details
Equipment ID
15687
15687
Inspection Date
5/23/2017
5/23/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Johnny Coats
Johnny Coats
Relief Valve Pressure
Slide
Governor Rope Pull
600
600
Door Closing Force
26
26
External ID
771deb82-f7a8-4453-8931-11b8b7f73a52
771deb82-f7a8-4453-8931-11b8b7f73a52
Location
Jackson County Detention Center
1300 CHERRY ST, KANSAS CITY, MO
1300 CHERRY ST, KANSAS CITY, MO
Owner
Jackson County
303 W WALNUT ST, INDEPENDENCE, MO 64050-3849
303 W WALNUT ST, INDEPENDENCE, MO 64050-3849
Billing
Attn: Jackson County
308 W KANSAS AVE, INDEPENDENCE, MO 64050-3728
308 W KANSAS AVE, INDEPENDENCE, MO 64050-3728
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Main hoisting ropes undersized. Min.594 actual .590 | 5/20/2019 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Gibs on landing doors worn/loosening. | 10/29/2020 |
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)6 | No | No | Guide rollers worn. | 10/29/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | No | No | Landing door gibs badly worn. | 10/29/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)7 | No | No | Landing door interlock missing cover. FL 4 | 10/29/2020 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | No CW runby in pit. | 5/13/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide MCP, or location of MCP in machine room. | 10/29/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Provide fire service testing log in machine room, and document monthly testing. | 10/29/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Debris on car top. | 10/21/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Debris in pit. | 10/21/2021 |
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)6 | No | No | Guide rollers worn, causing noisy ride. | 10/21/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in machine room. | 8/30/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Remove 2nd FFS recall keyswitch from G landing, closest to car 3. It is not necessary, and does not work. | 8/30/2022 |