Inspection
Inspection Details
Equipment ID
2846
2846
Inspection Date
11/17/2022
11/17/2022
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
F. Scott Gibson
F. Scott Gibson
Mechanic Name
Michael Bales
Michael Bales
Relief Valve Pressure
Slide
unknown
unknown
Governor Rope Pull
unknown
unknown
Door Closing Force
25
25
External ID
67f80017-abbc-4068-a344-c95432dfda5a
67f80017-abbc-4068-a344-c95432dfda5a
Location
Hotel Bothwell
103 E 4TH ST, SEDALIA, MO
Phone: (660) 826-5588
103 E 4TH ST, SEDALIA, MO
Phone: (660) 826-5588
Owner
Attn: Furnell Investments
Furnell Investments
501 S Ohio Ave, Sedalia, MO 65301
Phone: (000) 000-0000
Furnell Investments
501 S Ohio Ave, Sedalia, MO 65301
Phone: (000) 000-0000
Billing
Attn: Hotel Bothwell
Hotel Bothwell
103 E 4th St, Sedalia, MO 65301
Phone: (000) 000-0000
Hotel Bothwell
103 E 4th St, Sedalia, MO 65301
Phone: (000) 000-0000
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency phone not working. Alarm bell ok. | 11/17/2022 | |
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.2-211.8 | x | x | Mod in 2004, Phase I 2.27.3.1.6(a) violation recalled to alternate floor. Phase 11. 2.27.3.3.1 Phase ii operation not functional Red Tagged Car. | 2/24/2023 |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | x | Machine room door must be self-closing and self-locking. | 3/31/2023 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | x | Wall separating machine room is combustible material. Not fire rated | 3/31/2023 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | x | Large plumbing pipe in access path. Variance is requested. | 3/31/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)5 | x | Ladder needed in pit | 3/31/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | x | Light needed in pit | 3/31/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)7 | x | Additional stop switch needed in deep pit | 3/31/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | x | A wooden partial platform between pit floor and buffers attached to the front of hoistway wall is not needed for elevator operation. | 3/31/2023 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door must be self-closing and self-locking | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Needs non combustible separation of machine room | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Existing pipe prevents unobstructed path to machine room | |||
MO Minimum : Elevators | (I) - Pits | (I)5 | Ladder needed in pit | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Light needed in pit | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Wooden platform in pit not needed for elevator operation | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Needs pit light | |||
MO Minimum : Elevators | (I) - Pits | (I)5 | Needs pit ladder | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Wooden platform in pit | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Need unobstructed path to machine room. Existing large plumbing pipe may need variance. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light mounted but not wired yet Need to complete | |||
MO Minimum : Elevators | (I) - Pits | (I)5 | Pit access ladder needed to be installed |