Inspection
Inspection Details
Equipment ID
19885
19885
Inspection Date
11/21/2022
11/21/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
James VanZant
James VanZant
Mechanic Name
Bryan Henson
Bryan Henson
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
adaf0bfc-d24f-4883-be97-bb4fa9c6dff8
adaf0bfc-d24f-4883-be97-bb4fa9c6dff8
Location
JC Penney- Springfield
2825 S Glenstone Ave, Springfield, MO
Phone: (417) 883-4220
Email: svance3@contractor.jcp.com
2825 S Glenstone Ave, Springfield, MO
Phone: (417) 883-4220
Email: svance3@contractor.jcp.com
Owner
Attn: JC Penney #1188-2 Springfield
JC Penney #1188-2 Springfield
2825 S Glenstone Ave, Springfield, MO 65804
Phone: (214) 429-9416
Email: salvar83@jcp.com
JC Penney #1188-2 Springfield
2825 S Glenstone Ave, Springfield, MO 65804
Phone: (214) 429-9416
Email: salvar83@jcp.com
Billing
Attn: Joseph Tyler
Penney OpCo., LLC
2401 S Stemmons Frwy, Unit 4000, Lewisville, TX 75067
Phone: (469) 352-7327
Email: jtyler15@jcp.com
Penney OpCo., LLC
2401 S Stemmons Frwy, Unit 4000, Lewisville, TX 75067
Phone: (469) 352-7327
Email: jtyler15@jcp.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | truss , upper & lower end need clean down | 6/24/2019 |
| conversion | conversion | n/a | No | No | Upper and lower lights & guasrds in truss need replaced | 6/24/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | needs current certificate posted | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | 2019-2020: Step demarcation lights not working upper and lower (2nd year violation) | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 6.1.7 | No | No | Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Escalator machine spaces(pits) shall be kept clean and free from excessive debris. | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 6.1.3.5.6 | No | No | :Replace broken step demarcation sections. Reinspection within 30 days | 1/14/2022 |
| A17.1-2016 : Elevators | 7.9 - Steps and upthrust device | 8.6.8.6 | No | No | Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 6.1.7 | No | No | Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Escalator machine spaces(pits) shall be kept clean and free from excessive debris. | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 6.1.3.5.6 | No | No | :Replace broken step demarcation sections. Reinspection within 30 days | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6 | Yes | No | Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6 | Yes | No | Replace broken step Demarcation sections | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6 | Yes | No | Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) | 9/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 6.1.3.4 (Hand rails) (Re-Inspection) | Yes | No | /7.3.1(a) Handrails will be free of major cracks and pinchpoints. Replace both Handrails. REINSPECTION REQUIRED | 11/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 6.1.3.5.6 | Yes | No | Replace loose/damaged/broken step demarcation sections. REINSPECTION REQUIRED | 11/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | Yes | No | 8.1.2: Escalator machine spaces(upper and lower pits) shall be kept clean and free from excessive debris. MULTI-YEAR VIOLATION= | 11/21/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform annual clean down | 12/1/2023 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | Preform annual clean down | 8/9/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | replace damaged hand rails | 9/11/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.6.2(i) Step Demarcation | No | No | provide operational demarcation lights | 9/11/2025 |