Inspection
Inspection Details
Equipment ID
7415
7415
Inspection Date
11/22/2022
11/22/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Mitchell McNeely
Mitchell McNeely
Mechanic Name
John Palmer, Jr
John Palmer, Jr
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
24
24
External ID
c638656d-f1f9-4d04-9806-2f4281332c94
c638656d-f1f9-4d04-9806-2f4281332c94
Location
Le Meridien Clayton
7730 Bonhomme Ave, Clayton, MO
Phone: (314) 863-0400
7730 Bonhomme Ave, Clayton, MO
Phone: (314) 863-0400
Owner
Attn: Silverwest-I Clayton, LLC
Silverwest-I Clayton, LLC
101 University Blvd, Ste 200, Denver, CO 80206
Phone: (314) 719-4328 Ext: 7126
Email: arta.dora@lemeridienclayton.com
Silverwest-I Clayton, LLC
101 University Blvd, Ste 200, Denver, CO 80206
Phone: (314) 719-4328 Ext: 7126
Email: arta.dora@lemeridienclayton.com
Billing
Attn: Silverwest-I Clayton, LLC
Silverwest-I Clayton, LLC
101 University Blvd, Ste 200, Denver, CO 80206
Phone: (314) 863-0400
Email: ron.blake@lemeridienclayton.com
Silverwest-I Clayton, LLC
101 University Blvd, Ste 200, Denver, CO 80206
Phone: (314) 863-0400
Email: ron.blake@lemeridienclayton.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.8 - Top emergency exit | 8.11.2.1.3(l) | No | No | Emergency hatch shall be operable, remove temporary weights from top of hatch. | 4/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 3/2/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Maintenance control program shall be on-site. | 4/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.8 - Top emergency exit | 8.11.2.1.3(l) | No | No | Emergency hatch shall be operable. Remove temporary weights from top of hatch. | 4/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written maintenance control program shall be provided on site. | 4/14/2022 |
| MO Minimum : Elevators | (D) - Brakes | (D)2 | Yes | Yes | Brake will not hold 125% capacity | 7/30/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No maintenance control program in the machine room | 4/14/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Maintenance control program is not filled out | 4/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 8/9/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Provide testing of the elevator on emergency power. | 4/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.12 - Standby power selection switch | 2.27.2 | Yes | No | Provide testing of the selector switch. | 4/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Governor rope tension weight in pit, not adjusted, provide. | 8/9/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Observed emergency power jewel in lobby is on, repair as needed. | 4/4/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean oil off floor in pit. | 10/14/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)6 | Yes | No | Re-install buffer switches on car and counterweights. | 10/14/2025 |