Inspection
Inspection Details
Equipment ID
756
756
Inspection Date
9/21/2018
9/21/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Jamon Gray
Jamon Gray
Relief Valve Pressure
310
310
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
757b15f6-bb5e-4c3b-ae11-96f8a05fa77e
757b15f6-bb5e-4c3b-ae11-96f8a05fa77e
Location
Franciscan
620 W SCOTT ST, SPRINGFIELD, MO
620 W SCOTT ST, SPRINGFIELD, MO
Owner
Franciscan Villa LP
1630 N JEFFERSON AVE, SPRINGFIELD, MO 65803-2819
1630 N JEFFERSON AVE, SPRINGFIELD, MO 65803-2819
Billing
Attn: Franciscan Villa LP
1525 E REPUBLIC RD STE B100205, SPRINGFIELD, MO 65804-6527
1525 E REPUBLIC RD STE B100205, SPRINGFIELD, MO 65804-6527
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | ceiling panels removed and smoke detector covered | 9/26/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | No | No | 1.6 telephone does not work | 9/26/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | non elevator items stored in machine room | 12/17/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | ceiling panels in machine room need replaced | 12/17/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | interior panels need replaced to prevent bulb breakage | 12/17/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | telephone does not work disconnected | 10/22/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | needs current certificate posted | 12/17/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | B(11)/1.6.1 : Alarm bell shall work with power loss. (REINSPECTION REQUIRED) | 10/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | G/8.6.5.5.2 Pit scavenger pump will be removed or routed to a measurable container. | 10/31/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept free of excessive debris. | 10/31/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | B(11)/1.6.1 : Alarm bell shall work with power loss. (REINSPECTION REQUIRED) | 10/5/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Door operator belts cracked/dry rotted. Replace all. | 1/1/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept free of excessive debris.(2020 and 2021) | 1/1/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | B(11)/1.6.1/ : 2-way communication device shall work and give proper location (REINSPECTION 15days) | 9/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light & alarm bell - needs new battery. Re-inspection required | 7/27/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all non elevator related items from machine room | 10/31/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current operating certificate in machine room | 10/31/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Provide phase one instructions at main level hall station | 10/31/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Provide operational telephone inside elevator cab | 8/27/2024 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5.1 Examination and Maintenance | No | No | Cylinder is damaged and no longer able hold a seal around the packing | 6/10/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | provide operational telephone | 12/9/2025 |