Inspection
Inspection Details
Equipment ID
757
757
Inspection Date
9/21/2018
9/21/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Jamon Gray
Jamon Gray
Relief Valve Pressure
Slide
Governor Rope Pull
n/a
n/a
Door Closing Force
18
18
External ID
42395251-ba98-4ffa-ab9f-5fa8e69ec978
42395251-ba98-4ffa-ab9f-5fa8e69ec978
Location
Franciscan
620 W SCOTT ST, SPRINGFIELD, MO
620 W SCOTT ST, SPRINGFIELD, MO
Owner
Franciscan Villa LP
1630 N JEFFERSON AVE, SPRINGFIELD, MO 65803-2819
1630 N JEFFERSON AVE, SPRINGFIELD, MO 65803-2819
Billing
Attn: Franciscan Villa LP
1525 E REPUBLIC RD STE B100205, SPRINGFIELD, MO 65804-6527
1525 E REPUBLIC RD STE B100205, SPRINGFIELD, MO 65804-6527
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | water in pit rusting springs and channels | 12/17/2019 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | telephone needs to be replaced | 10/22/2019 | |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | needs current certificate posted on site | 12/17/2019 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | pit light not working | 12/17/2019 | ||
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | G(1)/8.6.4.15/1.5.1(b) : Emergency lighting shall work with power loss. (Reinspection required) | 10/5/2021 | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | I(1)/106.1 Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak. 8" water in pit | 10/15/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | G(1)Emergency/auxiliary lighting shall work with power loss. (2020 & 2021 VIO) | 9/7/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Car Door restrictor shall work. | 9/7/2022 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept dry. 4” water in Pit, drain, remove rust from pit channels, repaint, repair water leak. (2020 & 2021 violation) | 10/15/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | G(1) CARTOP: Clean/remove debris and metal dust covers | 10/15/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | G(1) Adjust all upthrust roller bearings for proper clearance, currently as much as 0.125”. | 10/15/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Machine Room Fire Extinguisher shall have current monthly/annual test tag. Expired | 10/15/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room lighting needs to be repaired | 10/15/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self-closing and self-locking (currently deadbolt, not self locking) | 10/15/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | x | Machine room door needs to be self closing & self locking. Re-inspection required | 7/27/2023 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display current operating certificate in machine room | 10/24/2023 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Provide current state operating certificate in machine room | 8/27/2024 |