Inspection
Inspection Details
Equipment ID
13229
13229
Inspection Date
11/17/2022
11/17/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
5d48ef82-9a52-4e27-841b-3889e40f291f
5d48ef82-9a52-4e27-841b-3889e40f291f
Location
Art Loft
1531 Washington Ave, St. Louis, MO
Phone: (314) 436-6545
1531 Washington Ave, St. Louis, MO
Phone: (314) 436-6545
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting shall be guarded. | 9/13/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room doors shall be self-closing and self-locking. | 9/13/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be operational. | 5/8/2019 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)6 | Yes | No | Make the door close button operational. | 5/8/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)6 | No | No | Display a current state operating certificate. | 9/13/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting shall be guarded. | 5/1/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Emergency exit shall be properly secured. | 5/1/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Fire service car call cancel button is not operating and shall be repaired and tested. | 10/6/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Could not gain access to walk in pit. Key to access the pit shall be kept on-site for safe access to the pit. All inspection items relating to the pit still need testing. | 10/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency Phone Inoperative | 5/6/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine Room Door not self closing or self locking | 5/13/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Extension cords shall not be ran across the machine room floor | 5/13/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | All junction boxes in the elevator machine room shall be covered | 5/13/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing and locking. Key on site for access | 8/5/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | Yes | Counterweight buffer inoperable. Needs replaced. | 8/5/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light is not working. Repair or replace item(s) | 8/5/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)7 | No | No | Repair pit switch toggle. Works but partially broken off | 8/5/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Close up hole in the hoistway at pit level across from access door | 8/5/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Pit has access door. It needs to be self closing and self locking with a key on site for access | 8/5/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Electrical cords are ran across the floor of machine room | 8/5/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Testing incomplete. Safety test, slide, and car and counterweight buffer test. Governor spin test | 8/4/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Current means to remove water from pit/sump has a hose blocking pit door from closing. | 5/1/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Hole in Hoistway,pit level. See previous reports. | 5/1/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Broken tile on cab floor, this is a tripping hazard. Repair as needed. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide code compliant machine room door. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide hand rail(s) on ladder to machine room, for safe and convenient access. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove old a/c unit from the machine room. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Observed numerous electrical violations still outstanding from previous reports. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Enclose space around current a/c unit. Remove or treat wood currently there. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Repair/replace broken machine room windows. | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide code compliant fire extinguisher in the elevator machine room. | 5/1/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Hole in hoistway at pit level | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide code compliant machine room door | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide handrails on ladder to machine room | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove old a/c unit from machine room | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Observed numerous electrical violations | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Enclose space around current a/c unit | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Repair/replace broken machine room windows | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide code compliant fire extinguisher in machine room | 5/1/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Repair hole in elevator hoistway wall at pit level | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide handrail on steps to machine room | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide fire extinguisher in machine room | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing, self locking and operable from inside the machine room without the use of a key | 5/1/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Repair hole in elevator hoistway wall at pit level | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide handrail on steps to machine room | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide fire extinguisher in machine room | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing & self locking | 5/1/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | Yes | No | Gas charged buffers shall be provided with buffer switches | 4/9/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Yes | No | Provide currently serviced extinguisher in the machine room | 4/9/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide self closing self locking door on the machine room | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide currently serviced extinguisher in the machine room. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The elevator walk in pit door shall be self closing, self locking and operable from inside the machine room without the use of a key | 5/1/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Repair hole in elevator hoistway wall at pit level. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | A permanent, safe, and convenient means of access to the machine room is required. The current access door does not meet the criteria addressed in the latest code. Construct or modify access to the machine room to be safe and convenient for maintenance personnel. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Repair/replace broken machine room windows. | 5/1/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Broken tile on cab floor, this is a tripping hazard. Repair as needed. | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | The position indicating or “PI” device in the car was not operational on the day of inspection. Repair “PI” device to indicate the position of the elevator car. | 5/1/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator ADA telephone inside the elevator is not working properly. Check and repair the programming of this phone for proper operation and passenger safety. | 5/9/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. | 5/1/2024 |
| A17.1-2016 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 8.6.4.4 | Yes | Yes | The counterweight buffer has been submerged in water and shall be replaced due to water damage. Reinspection required and red tag issued. | 5/9/2024 |
| A17.1-2016 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 8.6.4.4 | Yes | Yes | The counterweight buffer switch has been submerged in water and shall be replaced. Reinspection required and red tag issued. | 5/9/2024 |
| A17.1-2016 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 8.6.4.4 | Yes | Yes | The car buffer is a gas assisted buffer that requires a buffer switch to remove the elevator from service if the gas in the buffer fails to properly return the buffer properly. There is no switch and this was previously sited on 6/7/23. Reinspection required and red tag issued. | 5/9/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Multiple non elevator related electrical wiring in the hoistway and the pit shall be removed from the area. | 5/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Yes | No | 8.6.1.7.5 Devices Not Covered in 8.6-The electrical disconnect for the lighting inside the elevator cab also disconnects the lighting in the means of egress stairwell. With this condition in place, lighting will be compromised in an emergency situation for passengers and emergency personnel. | 5/9/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The testing has not been completed on the elevator at this time, the elevator was placed out of service. Only a machine room, pit, in car inspection was performed, a full inspection shall be performed before the annual is completed. Reinspection is required. | 5/9/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | In Car Position Indicator not working | 4/9/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | Yes | Fire Service PH II does not return to PH I when keyswitch is turned to"off" | 4/9/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Pit Shall be cleaned. | 6/9/2026 |