Inspection
Inspection Details
Equipment ID
1863
1863
Inspection Date
11/23/2022
11/23/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
460
460
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
1f46e2a3-7dd1-4213-99bf-c3e17bf0ca89
1f46e2a3-7dd1-4213-99bf-c3e17bf0ca89
Location
Blueberry Hill Restaurant
6504 DELMAR BLVD, UNIVERSITY CITY, MO
Phone: (314) 727-4444
6504 DELMAR BLVD, UNIVERSITY CITY, MO
Phone: (314) 727-4444
Owner
Attn: Edwards, Joe
Edwards, Joe
6504 Delmar Blvd, University City, MO 63130
Phone: (314) 727-4444 Ext: 13
Email: media@blueberryhill.com
Edwards, Joe
6504 Delmar Blvd, University City, MO 63130
Phone: (314) 727-4444 Ext: 13
Email: media@blueberryhill.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)2(D) | Emergency light not working. Reinspect. 1.6 | 8/29/2018 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Fire extinguisher outdated. 2.7 | 8/29/2018 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean and dry. | 10/21/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Sump pump needs to be repaired or replaced so that it operates automatically. | 10/21/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Lighting and electrical plugs in pit shall be replaced. If installed below 4 ft it needs to be NEMA 4 waterproof. | 10/21/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Buffer stands and pit channels are rusted. Should be rust proof to prevent further damage. | 10/21/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Hydraulic lines should be checked and rust proofed to prevent further damage. | 10/21/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working. Only 14 volts on phone line. | 10/15/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Repair emergency light, alarm bell and phone. | 10/15/2020 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Emergency phone does not work. REINSPECT REQUIRED | 8/12/2021 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Sump pump in pit is not pumping. There is standing water in the pit. All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency Light and Bell do not work when normal power is removed | 8/9/2024 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | There is standing water in the pit. The sump pump does not turn on automatically. Pits shall be kept clean, dry, and clear of debris. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The pit light does not illuminate | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | x | Emergency Light does not work when normal power is removed. The alarm bell does work on backup power | 9/3/2024 |