Inspection
Inspection Details
Equipment ID
10863
10863
Inspection Date
7/18/2018
7/18/2018
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Vincent Daus
Vincent Daus
Mechanic Name
Jeff Thieme
Jeff Thieme
Relief Valve Pressure
Slide
34"
34"
Governor Rope Pull
100/800
100/800
Door Closing Force
20
20
External ID
f1c45d00-e76e-4294-a6df-c784f26e82fc
f1c45d00-e76e-4294-a6df-c784f26e82fc
Location
St. Louis Place
200 N BROADWAY, SAINT LOUIS, MO
200 N BROADWAY, SAINT LOUIS, MO
Owner
Cushman Wakefield Inc
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102-2753
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102-2753
Billing
Attn: Cuchman Wakefield
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102-2753
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102-2753
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | Yes | No | Test emergency power when all elevator modernizations have been completed. | 1/23/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.11.2.1.4(l) | Yes | Yes | Replace the smoke detector on the 7th floor. | 1/23/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Need a maintenance control program on site | 1/24/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair emergency phone in car | 2/6/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/5/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/5/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire Service shall be operational. This violation must be corrected in 14 days per the State of Missouri. | 2/24/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | Fire service testing must be documented monthly. The form is present in the MCP but, has not been logged. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.11.1 | No | No | PM/Repair/callback logs not being consistently documented. |