Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) Yes No Car door restrictor battery back-up does not work. 4/17/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 No No Cut off car top channel blocking emergency exit. 10/20/2020
MO Minimum : Elevators (F) - Electrical Switches (F)9 No No Disconnecting means are hard to get to causing a safety hazard. Mechanic has to touch to shut diconnect
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Fire extinguisher needs to be serviced. 2.7.1 11/7/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Fasia in hoistway between 2nd and 3rd floor is loose/missing screws. 10/20/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Replace hatch latch back up battery. 10/20/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Pit light does not work
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No OSV is not sealed and must have a category 5 weight test within 90 days or less
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) Yes No Perform the required Cat 5 Tests on the overspeed valve 10/12/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Need to perform the required Cat 5 testing on the plunger gripper. Re-inspection required
conversion conversion n/a No No Replace roustabout fitting on supple line near pump unit 11/7/2018
conversion conversion conversion - reinspect Yes No Cut off Channel on car top blocking escape hatch. 165" clear opening required. 9/20/2018
conversion conversion n/a No No Replace bad battery in hatch latch for proper operation. 11/7/2018