MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
Elevator cab phone does not work, needs repaired. Re-inspection required
|
10/4/2024
|
MO Minimum : Elevators
|
(D) - Brakes
|
(D)1
|
x
|
x
|
Test brake with 125% of rated load. Reinspect within 30 days.
|
12/17/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Written maintenance control program shall be kept on site for each elevator.
|
9/22/2021
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
Test car safeties with rated load.
|
12/17/2019
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to test car safeties at rated speed with rated load. Re-inspection required
|
10/4/2024
|
A17.1-2016 : Elevators
|
2.43 - Emergency Brake, Ascending Car Overspeed, and Unintended Car Movement Protection
|
8.6.4.20.11 (Re-Inspection)
|
x
|
x
|
Performed unintended movement test. Car movement in the down direction with 125% of rated load was 87 inches. Movement in the up direction with no load was 56 inches. Elevator must not move more than 48 inches. Red-tagged, removed from service. Re-inspection required
|
10/4/2024
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be displayed in the machine room
|
6/29/2023
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be displayed in the elevator machine room
|
10/4/2024
|