MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Car top electric junction box missing cover.
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
x
|
|
Car top electric j/b missing cover.
|
1/7/2025
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)7
|
x
|
|
Door force exceeds code.
|
1/7/2025
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)7
|
x
|
|
Car door closing force is way above 30 lbs and shall be adjusted to 30 lbs or below. Re-inspection required
|
3/26/2024
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)7
|
x
|
|
Car door force exceeds code, adjust as needed.
|
3/26/2024
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)7
|
|
|
The elevator car door closing force is over the maximum allowable force of 30lbs. Readjust door closing force to be less than 30lbs. Reinspection required.
|
3/26/2024
|
A17.1-2016 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
The bottom guide rollers on the counterweight are cracked and shall be replaced.
|
3/26/2024
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
8.11.2.1.3(r)
|
|
|
A receptacle box is missing its cover plate on top of the car exposing electrical connections. The cover plate shall be reinstalled to limit accidental contact by maintenance and emergency personnel.
|
3/26/2024
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
x
|
Phase I recall not working, car removed from service.
|
3/26/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
x
|
|
Bottom c/w roller guides bad, replace.
|
1/7/2025
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Counterweight guide rollers are deteriorated and causes unsafe condition. Re-inspection required
|
3/26/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Top and bottom counterweight roller guides worn, replace as needed.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
x
|
|
Counterweight rollers are deteriorating and shall be replaced. Re-inspection required
|
3/26/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Provide testing of the elevator on emergency power.
|
3/26/2024
|
A17.1-2016 : Elevators
|
4.12 - Standby power selection switch
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Provide testing of the elevator emergency power selector switch (lobby).
|
3/26/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
|
|
Clean the car top.
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Adjust car door close pressure to under 30lb.
|
11/16/2018
|
conversion
|
conversion
|
n/a
|
|
|
Handi-box cover on cart top is missing
|
2/20/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace or reinforce catwalk in pit
|
2/20/2019
|
conversion
|
conversion
|
n/a
|
|
|
No fire extinguisher in machine room
|
2/20/2019
|