Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)2 Door needs to be self locking/closing 10/12/2020
MO Minimum : Elevators (I) - Pits (I)1 Elevator pit must be keep dry and clean. Remove the oil from pit can overflow.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need maint records. KONE NEEDS TO SUPPLY 10/12/2020
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Need Phase I and II operating instructions 10/12/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone not working--building vacant / being sold 8/24/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Pickup rollers need to be changed 10/12/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x Violation A17.1 Rule 102.2(c)(3) the means to automatically disconnect the main line power supply to the affected elevator prior to the application of water, with a Shunt trip Device and Heat Device as well as a Smoke Device to send elevator to the main floor egress.
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Violation of A17.1 Rule 102.2(c)(1) Building Sprinkler Lines have been brought thru the Elevator Machine Room with 3 penetration points.. Lines must be removed. points 8/1/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements x Violation of A17.1 Rule 102.2(c)(3) The means shall be provided to automatically disconnect the main line power supply to the affected elevator upon or prior to the application of water. 8/1/2024