MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)3
|
x
|
x
|
Top landing hoistway door interlock is broken, allowing the elevator to run with the doors open, the door is hanging by the chains, the door is off track
|
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)3
|
|
|
The car gate on the top landing side is off track and the two panels have separated and are not interlocked together, can close the bottom panel without moving the top panel
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
Provide maintenance control program
|
4/3/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Replace worn belts on on pump unit
|
4/3/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.7 Record of Oil Usage
|
|
|
Provide an oil log and update oil usage
|
4/3/2025
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Clean oil and oil dry from equipment room floor
|
4/3/2025
|
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)4
|
|
|
repair the muffler, it leaks and does not have a drip pan under it
|
6/19/2020
|
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)4
|
|
|
Mitigate oil leaks from pump unit
|
4/3/2025
|