Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 2/9/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Provide existing machine room lights to work.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator related items from the elevator machine room.
A17.1-2016 : Elevators 1.17 - Standby power operation 3.26.10 x Repair inoperative ERU device
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV is not sealed and must have a cat 5 weight test performed 12/1/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Provide existing battery backup lowering unit to work properly. 10/7/2024
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Supply up to date serviced fire extinguisher
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 3.27.1 Phase I Emergency Recall Operation After Device Actuation x x Car emergency stop switch not overridden
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.