Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting The cab ceiling is of the open egg crate type which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by a plastic sleeve or some other means to properly protect passengers 8/8/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light does not work. 6/25/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 8/8/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency alarm bell does not work. 6/25/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 2/7/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x This elevator has an overspeed valve device installed that is now required to have a 5 year full load test performed. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Overspeed valve shall be tested within the next 30 days, this is the second notice. 3/22/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The 5 year annual test has not been completed, the overspeed valve shall be tested. 3/22/2023
A17.1-1996 : Elevators 2.4 - Machine space 101.1a Ceiling tiles have been removed in the machine room, the ceiling tiles shall be reinstalled to maintain the fire resistance rating of the machine room. 8/8/2023
A17.1-1996 : Elevators 2.4 - Machine space 101.1a Ceiling tiles have been removed in the machine room, the ceiling tiles shall be reinstalled to maintain the fire resistance rating of the machine room 8/8/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) A written MCP shall be in place to maintain the equipment in compliance with the state requirements 2/4/2023
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 OSV test needs to be done on or before next inspection 2/4/2023