Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test not complete. Need to test hoistway doors, gate switch, slack tape switch, hoist ropes, car top equipment, pit equipment, soft set safety, no load car and counterweight buffer test, governor switch, escape hatch, top and bottom final and directional limits, runby, pit switches
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Replace broken shackle springs for suspension ropes in machine room. 6/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No Replace 2 broken shackle springs on hoisting cable shackles. 6/15/2021
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Fire service needs to be tested. Re-inspection required 7/8/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No The testing has not been completed on the elevator at this time. Emergency power operation shall be performed before the inspection is completed. 12/5/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Need to test elevator for operation on emergency power. Re-inspection required 8/21/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone in elevator cab does not work on battery backup or normal power, needs repaired. Re-inspection required 8/21/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Emergency Power needs to be tested - Test not completed 9/22/2025
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage No No Call Cancel button shall be labeled. 9/22/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Current operating certificate shall be displayed in the machine room 9/22/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the current operating certificate shall be displayed in the machine room 9/22/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Traction sheave liner is deteriorated and needs replacing 9/22/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No A rope saver is worn on drive sheave and shall be replaced. 9/22/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Current Operating Certificate shall be displayed in the machine room 10/10/2025