Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Repair lights above hoist machine to provide required illumination 8/12/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace defective right top post roller on counterweights 8/12/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the current operating certificate shall be displayed in the machine room 8/12/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Suspension ropes have broken shackle springs on the car & counterweights, need to replace shackle springs 8/12/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Machine to Motor coupling bushings are deteriorated and shall be replaced. 8/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Machine bed plate isolations pads are deteriorated and shall be replaced. 8/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Machine bed plate isolations pads are deteriorated and shall be replaced.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Machine to Motor coupling bushings are deteriorated and shall be replaced.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone shall be operational
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal Yes No Repair inoperative Phase l fire recall visiual indicator 12/7/2023
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes Yes Hoist ropes have broke lays in all 4 ropes in multiple sections. Hoist ropes shall be replaced.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Emergency Power and Fire Service shall be tested 8/15/2026
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes Yes Hoist ropes have broke lays in all 4 ropes in multiple sections. Hoist ropes shall be replaced. 8/15/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Need to test elevator for operation on emergency power. Re-inspection required 8/12/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone shall be operational 8/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Elevator cab emergency lights do not work, need repaired. Re-inspection required 8/12/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Repair inoperative emergency Lights 12/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2.5 Rope Tension (Re-Inspect) Yes No Replace broken shackel springs on car and counterweight ends 12/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2.5 Rope Tension (Re-Inspect) Yes No Replase missmatched shackle spring on counterweight 12/7/2023
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes No Suspension ropes are below minimum diameter. Replace within 30 days. 11/11/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency bell is not working. Re-inspection required 7/8/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete, need to perform 125% brake test. Re-inspection required 7/8/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete, need to perform full load buffer test for car & counterweight. Re-inspection required 7/8/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete, need to perform full load safety set. Re-inspection required 7/8/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete, need to test spin governor. Re-inspection required 7/8/2022
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Emergency power operation needs to be tested 12/7/2023