Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 GENERAL MAINTENANCE REQUIREMENTS: WRITTEN MCP, WRITTEN TEST PROCEDURES FOR CAT 1 TEST & OVERSPEED VALVE TEST; MCP SHALL BE ON JOB
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces A17.1 2004 8.6.4.8.2 Equipment in Machine Rooms 8.6.4.8.2 Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine rooms and machinery spaces. (OWNER) (OWNER SIGN OFF ON VIOLATION REMOVED) THIRD OFFENSE
conversion conversion conversion - reinspect x Replace phase one key switch. Tumbler assembly wore out, allowing any key to activate - re-inspect. 7/15/2019
conversion conversion conversion - reinspect x Repair inoperative emergency phone - re-inspect. 7/15/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting x EMG LIGHT UNIT NOT WORKING, BATTERY GOOD. RE-INSPECTION REQUIRED. 6/10/2021
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x A17.1 - 8.6.5.16.5 OVER SPEED VALVE NOT SEALED. PERFORM REQUIRED 5 YR OSV TESTING WITHIN 90 DAYS, PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION BY 9/10/2021 6/8/2022
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x A17.1 - 8.6.5.16.5 OVER SPEED VALVE NOT SEALED ( PERFORM REQUIRED 5 YR OSV TESTING WITHIN 30 DAYS, PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION BY. SECOND CITING OF UNSEALED OSV (6/10/21). 7/22/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting x A17.1 2004 Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting. CAR EMGENCY LIGHTING SHALL WORK. (OTIS) RE-INSPECTION RQD 7/22/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces A17.1 2004 8.6.4.8.2 Equipment in Machine Rooms 8.6.4.8.2 Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine rooms and machinery spaces. (OWNER) 8/14/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate 11 CSR 40-5.100 State Operating Certificate and Local Operating Certificate (2) Display of State Operating Certificate. The owner, operator, lessee or agent of either shall post the operating certificate in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. For installations without an elevator room the state operating certificate shall be posted as directed by the chief elevator inspector. 8/14/2024