MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
8.6.2.1 The clips retaining the slide guides are missing. The plastic guides come out of the holders during normal operation.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
The machine room door is corroded to the point that it will not self lock or self close. The machine room door shall be self closing and self locking.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency Phone in car fails to establish two-way communication
|
10/9/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency Phone in car fails to establish two-way communication (Mandatory Reinspect
|
10/3/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
x
|
x
|
8.6.3.10.4 The hydraulic tank is badly corroded. There is an oil slick on one side possibly indicating the integrity of the metal is compromised.
|
10/3/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
x
|
x
|
8.6.4.19.5 The bottom limit and final limit do not actuate and stop the car from traveling down. On inspection, the car will land on the buffer and get slack on the ropes.
|
10/3/2024
|