MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x The car door restrictor device shall be repaired so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection is required. 9/6/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements The car top inspection light did not operate. Repair fixture/light for proper operation. 8/18/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. 3/16/2021
conversion conversion n/a When testing the audible signaling device (alarm bell) with the 110V disconnect in the machine room in the ?off? position, the device failed to sound, indicating that the back-up power device (battery) has failed. Repair for proper operation. 8/18/2020
conversion conversion n/a The hoistway doors are missing pick up rollers for the car door clutch to work properly. Replace missing pick up rollers. 8/18/2020
conversion conversion n/a The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. 8/18/2020
conversion conversion n/a The car top inspection light did not operate. Repair fixture/light for proper operation. 8/18/2020