Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide operational light in pit
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP in machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 203.8: Underside of wooden platforms shall be protected against fire, either appropriate steel or fire retardant paint. ( recoat previous paint for full coverage)
MO Minimum : Elevators (I) - Pits (I)1 I(1)/106.1 Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11.1.4(a) Elevators Placed in Inactive Status x x This unit will be inactive status until the owner decides whether to remove or modify. They owner is currently not using this unit because it only goes to two of the three floors in the building
conversion conversion n/a Problem in leveling both directions & cancelling calls--suspect relays 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits sump not working and water in pit 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.7 - Car leveling and anticreep devices 8.11.2.1.3(j) Elevator stops in leveling zone-will not level into floor--needs repaired 7/12/2020
MO Minimum : Elevators (I) - Pits (I)8 sump pump cover needs to be put back in place 7/12/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 machine room gate needs to be locked 7/12/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate needs curreent certificate posted 7/12/2020
MO Minimum : Elevators (I) - Pits (I)1 x Pit floor shall be kept free of water, remove all rust from pit equipment and replace all rubber gaskets at each fittings 30 day reinspection 3/29/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Provide operational emergency light and alarm 3/29/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11.1.4(a) Elevators Placed in Inactive Status x x Unit placed inactive , the owner does not use this unit because it only goes to 2 of the bldgs floors. They are planning on either modernizing on removing the unit next year 3/30/2023