Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Pit scavenger pump must be removed 4/4/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No Provide MCP in machine room 4/4/2023
MO Minimum : Elevators (I) - Pits (I)1 No No Pit floor shall be kept free of oil and water 4/4/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current state operating certificate in machine room 9/25/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No G/8.6.5.5.2 Pit scavenger pump will be removed or routed to a measurable container. 4/4/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Provide operational emergency light and alarm 5/2/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Provide operational telephone in elevator cab 5/2/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No Mechanical edge and Detector not working. Possibly falsely/accidentally Reported as fixed 7/12/20 by someone. Reinspection required. 3/2/2023
conversion conversion n/a No No air conditioner not cooling room 7/12/2020
conversion conversion n/a No No holes in cab next to push button pannel need to be covered 7/12/2020
conversion conversion n/a No No Machine room lights not working 7/12/2020
conversion conversion n/a No No safety shoe on gate not working in middle of gate 7/12/2020
conversion conversion conversion - reinspect Yes No Telephone calls no answer-need to go to 24 hr service-REINSPECT REQUIRED 8/29/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.1 - Door Re-opening device 8.6.4.13.1(c) Door Reopening Devices No No 1.1 safety shoe on gate does not work and needs new cover 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits No No I-1 pit needs to be cleaned of all oil and debree 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits No No MO MIN--pit needs to be dry and clean 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits No No Pit light not working 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.1 - Door Re-opening device 8.6.4.13.1(c) Door Reopening Devices No No electrical and mechanical gate safety defice to reopen gate does not work 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No needs current operating certificate posted 7/12/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No B(11)/1.6.1 : Alarm bell shall work with power loss. Alarm not working on 110/ light and bell not working on battery 3/2/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Telephone will not call out needs direct line to 24 hr service 12/5/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No alarm bell not working 11/1/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No 1.5 car emergency light not working 11/1/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No telephone is disconnected 11/1/2019
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.11.1.3 Emergency Phone not workng Alarm Functioning ( Mandatory Re-Inspection due in 14 days) Yes No provide operational telephone inisde cab