Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 2.14.7 x Cab lights need to be repaired or replaced to provide code compliant lighting. 1/21/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency communication line does not work. 1/21/2025
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Increase machine room lighting to 10 ft candles throughout, measured at the floor. 12/31/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide a written maintenance control program 11/8/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 Repair machine room door closer. Door to be self-closing and locking. 12/31/2020
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.8.2 x The distance between the face of the controller and the nearest obstruction shall be no less than 36". 1/21/2025
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.8.2 x The distance between the face of the controller and the nearest obstruction shall be no less than 36". Note: Customer may be applying for a variance.
conversion conversion n/a The elevator ADA telephone inside the elevator is not working properly. Check and repair the phone line of this phone for proper operation and passenger safety. 10/17/2018
MO Minimum : Elevators (H) - Machine Rooms (H)4 The elevator machine room cannot be used for storage. Remove the items being stored in the machine room to provide proper room for maintenance to be performed. A telephone cabinet has been dislodged from the wall that is impeding the area for proper maintenance to be performed. 10/17/2018
MO Minimum : Elevators (H) - Machine Rooms (H)2 The elevator machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. 10/17/2018
A17.1-2016 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The phone inside the car does not work. 1/21/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x There is a sprinkler at the top of hoistway, but no heat or smoke detector. 1/21/2025