Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x The car door restrictor device shall be adjusted so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection required. 5/25/2021
A17.1-1996 : Elevators 2.19 - Gears, bearings, and flexible couplings 1206.1a 1) All excess lubricant shall be cleaned from the equipment. Machine has gear oil on it from varies leaks, with the brake drum having oil on it, traction drive sheave having oil on it, etc. 5/1/2019
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 The emergency light fixture inside the elevator is not operational and needs to be repaired. 3/16/2022
conversion conversion conversion - reinspect x 4. The code under which this major alteration was performed requires means of two-way conversation on all automatic elevators. Phone isn?t functioning. 3/6/2019
conversion conversion n/a 3. Verify that the top emergency exit is hinged or otherwise attached to the car. This exit is not and shall be attached to car by some means. 7/23/2018
conversion conversion n/a 1. All excess lubricant shall be cleaned from the equipment. Containers used to catch leakage shall not be allowed to overflow. Machine has gear oil on it from varies leaks, with the brake drum having oil on it, traction drive sheave having oil on it, etc. 7/23/2018
conversion conversion n/a 5. Emergency operation of signaling devices, lighting, communication and ventilation, shall be maintained. 7/23/2018
conversion conversion n/a 2. Horizontally sliding or single section swinging doors of automatic elevators must be provided with door closers arranged to close an open door automatically if the car leaves the landing zone for any reason. During inspection the 3rd floor (4th Landing) & 4th floor ( 5th Landing) doors weren?t free enough to pass the door closing inspection. 7/23/2018