Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Adjust up-thrust roller bearings for proper clearance to door hanger track. (Multiple floors)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A code compliant MCP and related on-site documentation shall be provided. Note: No oil or fire service log for 2022 or 2023.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Current state operating permit shall be displayed.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting All car lamps shall work.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lighting needs to be repaired, 1 or more bulbs not working.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Replace missing "Do not use elevator in case of fire" signage on multiple floors.
MO Minimum : Elevators (S) - Fire Service (S)1 x x Elevator will not go into Phase 2 fire service. Elevator Red Tagged. Must be corrected before red tag is removed.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) Evacuation procedures are missing from the MCP.
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Fire service testing log is missing from the MCP.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x x Car did not pass the 15 minute standing test. Elevator Red Tagged.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Relief pressure shall be tested and documented.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace pit light. 1/14/2021
MO Minimum : Elevators (I) - Pits (I)1 Clean pit. 1/14/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Car door restrictor shall work through-out hoistway. 9/17/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x 2-way communication device very staticy per agent, could not understand most of our speech. 9/17/2024