Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone is not working. Re-inspection required 10/1/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x The car door restrictor is not working. Re-inspection required 10/1/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.4 x x A supplemental safety hand rail has been added to the top of the elevator car that strikes the hoistway ventilation duct at the top of the hoistway when the elevator travels up to its full travel. The ventilation duct is now disfigured and the hand rail has been bent. The duct work shall be repaired and the guard rail shall be re-fabricated to the clearances outlined by A17.1 2004a. No red tag issued as this condition has been present for a undetermined amount of time. 7/22/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.4 x x A supplemental safety hand rail has been added to the top of the elevator car that strikes the hoistway ventilation duct at the top of the hoistway when the elevator travels up to its full travel. The ventilation duct is now disfigured and the hand rail has been bent. The duct work shall be repaired and the guard rail shall be re-fabricated to the clearances outlined by A17.1 2004a. No red tag issued as this condition has been present for a undetermined amount. 3/17/2021