Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Clean pit 2/13/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Replace damaged rollers on counterweight 4/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Cotter pins are missing on counterweight tie rods. Repair 4/9/2024
conversion conversion n/a Plunger for restricted opening missing replace 2/13/2020
conversion conversion conversion - reinspect x Phase II door open inoperative repair 5/24/2019
conversion conversion conversion - reinspect x Emergency light inoperative 5/24/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work. Phone line problem 4/9/2024
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Counterweight runby is 0 inches. Shorten hoisting cables to provide 6 inches of counterweight runby. Re-inspection required 6/27/2024
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits x Need to clean debris from elevator pit. Re-inspection required 6/27/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Reinspection of the emergency phone and it did not work. Reinspect when repaired 9/23/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work, needs repair. Re-inspection required 10/5/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Car door restrictor does not work, needs repair. Re-inspection required 10/5/2022