Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace cover on duct on the car top
A17.1-1996 : Elevators 1.8 - Door closing force 1002.2(h) x Door close pressure shall be turned down to below 30 lbs. Re-inspection required
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone inoperative. Repair 10/3/2019
A17.1-1996 : Elevators 2.17 - Drive machine brake 207.8 x Uncontrolled motion, rope griper, inoperative. Repair 10/3/2019