Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Elevator broke duing testing, need to perform the following to complete inspection: pressure relief, door pressure, emergency phone & emergency lighting. Re-inspection required 11/18/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors Refasten cab floor rubber at car sill edge. 10/15/2019
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lighting shall not be less than 10 ft candles at floor level
MO Minimum : Elevators (I) - Pits (I)1 Sump pump does not work in the pit. Pit needs to be cleaned of debris and water
MO Minimum : Elevators (I) - Pits (I)8 Sump pump does not work in pit.
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)6 Upper left car guide shoe worn away. Unlined guide shoe assembly scraping rail, repair. 10/15/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace worn and missing guide shoes