Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)10 Top floor pull chain box wont lock
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage There is no fire service instructions on main landing
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x Fire hat in car did not light up 11/17/2022
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Repack hydraulic cylinder due to excessive oil leakage. Finish removing oil return line from hoistway and machine room that was used for scavenger pump. Remove scavenger pump
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No fire service instructions at 1st floor key switch
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lighting shall be no less than 10 foot candles at the floor