MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test incomplete, Need to perform 125% brake test, car & counterweight buffer test, full load set safeties, & unintended motion. Re-inspection required
|
12/11/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.17 - Standby power operation
|
8.11.2.2.7
|
x
|
|
Elevators connected to an emergency or standby generator shall be tested for operation on emergency or standby power. Re-inspection required
|
11/7/2022
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)1(B)
|
|
|
Counterweight runby is 0". Shorten suspension ropes.
|
12/11/2018
|