Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys Fire panel and phase 1 switch shall be keyed alike
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Secure car top emergency exit in the closed position
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x x Replace hoist cables due to diameter reduction. Cable stretched to excess allowing the counterweights to strike the buffer before the car reaches the up final limit 12/2/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x x Hoist ropes need shortened, counterweight landed on buffer springs before car could reach top final limit. Red tagged, Re-inspection required 12/6/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Repair fire recall phase 2. Car not returning to phase 1 when phase 2 car switch is turned to off position 12/2/2021