Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.4 - Drive machine and brake 8.11.4.2.4 x x Drive machine output shaft seal is compromised and leaking oil. Oil leaking on steps is a slip hazard and represents a life safety concern. Unit Red-Tagged and locked off for repairs. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.6.7 The top and bottom demarcation lights shall be operational. 12/2/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x Step indexing testing is required to be performed as part of the annual inspection. 11/6/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.6.8.1 x Cracked or damaged handrails that present a pinching effect shall be repaired or replaced. The left handrail has developed cracks on the sides and needs to be repaired or replaced.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022) 9/23/2021