ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.4 - Drive machine and brake
|
8.11.4.2.4
|
x
|
x
|
Drive machine output shaft seal is compromised and leaking oil. Oil leaking on steps is a slip hazard and represents a life safety concern. Unit Red-Tagged and locked off for repairs.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.5 - Lighting
|
6.1.6.7
|
|
|
The top and bottom demarcation lights shall be operational.
|
12/2/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Step indexing testing is required to be performed as part of the annual inspection.
|
11/6/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
8.6.8.1
|
x
|
|
Cracked or damaged handrails that present a pinching effect shall be repaired or replaced. The left handrail has developed cracks on the sides and needs to be repaired or replaced.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022)
|