Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.6.7 The top and bottom demarcation lights shall be operational. 12/2/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.4 - Drive machine and brake 8.11.4.2.4 x x Drive machine output shaft seal is compromised and leaking oil. Oil leaking on steps is a slip hazard and represents a life safety concern. Unit Red-Tagged and locked off for repairs. 8/2/2018
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022) 9/23/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.6.8.1 x Cracked or damaged handrails that present a pinching effect shall be repaired or replaced. The left handrail has developed cracks on the sides and needs to be repaired or replaced.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x Step indexing testing is required to be performed as part of the annual inspection. 11/6/2020