conversion
|
conversion
|
conversion - reinspect
|
x
|
|
All Electrical Equipment in the elevator shall be grounded. Rule H-7
|
1/28/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Car lighting needs to be protected.
|
3/4/2019
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)3
|
|
|
Hole in machine room floor needs to be covered.
|
3/4/2019
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Machine room needs to be kept clean.
|
3/4/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Provide explosion tubes over bulbs or guard to prevent breakage
|
2/25/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams
|
|
|
Provide up to date wiring prints.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Reprogram emergency phone to call a monitored line.
|
7/9/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Reprogram phone to ring to correct emergency number.
|
7/13/2021
|