Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) no current mcp on site 8/2/0222
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 need to remove pumpback sys. 8/2/2022
MO Minimum : Elevators (I) - Pits (I)1 pit has oil on the floor 3/17/2023
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 need phase two fire service signage car has phase one in it instead of phase two 3/17/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate no current cirt. posted 3/17/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate no current cirt. displayed 8/2/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation maint records not current 8/2/2022
A17.1-2016 : Elevators 2.14 - Code data plate 8.7.1.8 x Provide a code data plate reflecting the alteration and inspection criteria 3/8/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x phone not dialing out 3/21/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x emg. Lt. an bell not working 6/24/2021
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x door restrictor missing 6/24/2021
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x door restrictor missing 3/25/2021