Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection The use of oil recovery systems back to the tank prevents proper monitoring of oil loss from packing gland. 8/15/2023
MO Minimum : Elevators (H) - Machine Rooms (H)4 The elevator machine room cannot be used for storage. Remove the items being stored in the machine room to provide proper room for maintenance to be performed. 1/27/2026
MO Minimum : Elevators (H) - Machine Rooms (H)8 The lockable disconnect for the elevator cab lights does not disconnect the power as noted. Repair the disconnect to operate as designed. 1/27/2026